1,207 research outputs found

    Using Biobrane: Techniques to Make Life Easier

    Get PDF
    Aims: To facilitate the use of Biobrane for those burn care practitioners not familiar with this material. Methods: Two techniques have been developed through extensive use of Biobrane over many years, in both sheet and glove form. These techniques have been described and illustrated with photographs. Results: The use of these techniques has allowed the corresponding author to markedly reduce operating time and to easily apply the material single-handedly. Conclusion: Biobrane is a biosynthetic skin substitute primarily designed for the definitive treatment of superficial partial-thickness to mid-dermal burn injury. Once experienced with its use, the material is quite ubiquitous. The described techniques will facilitate the use of Biobrane for those not familiar with it

    Rationale and design of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary heart disease 2 trial (CE-MARC 2): a prospective, multicenter, randomized trial of diagnostic strategies in suspected coronary heart disease

    Get PDF
    Background: A number of investigative strategies exist for the diagnosis of coronary heart disease (CHD). Despite the widespread availability of noninvasive imaging, invasive angiography is commonly used early in the diagnostic pathway. Consequently, approximately 60% of angiograms reveal no evidence of obstructive coronary disease. Reducing unnecessary angiography has potential financial savings and avoids exposing the patient to unnecessary risk. There are no large-scale comparative effectiveness trials of the different diagnostic strategies recommended in international guidelines and none that have evaluated the safety and efficacy of cardiovascular magnetic resonance.<p></p> Trial Design: CE-MARC 2 is a prospective, multicenter, 3-arm parallel group, randomized controlled trial of patients with suspected CHD (pretest likelihood 10%-90%) requiring further investigation. A total of 1,200 patients will be randomized on a 2:2:1 basis to receive 3.0-T cardiovascular magnetic resonance–guided care, single-photon emission computed tomography–guided care (according to American College of Cardiology/American Heart Association appropriate-use criteria), or National Institute for Health and Care Excellence guidelines–based management. The primary (efficacy) end point is the occurrence of unnecessary angiography as defined by a normal (>0.8) invasive fractional flow reserve. Safety of each strategy will be assessed by 3-year major adverse cardiovascular event rates. Cost-effectiveness and health-related quality-of-life measures will be performed.<p></p> Conclusions: The CE-MARC 2 trial will provide comparative efficacy and safety evidence for 3 different strategies of investigating patients with suspected CHD, with the intension of reducing unnecessary invasive angiography rates. Evaluation of these management strategies has the potential to improve patient care, health-related quality of life, and the cost-effectiveness of CHD investigation

    Cardiovascular magnetic resonance of scar and ischemia burden early after acute ST elevation and non-ST elevation myocardial infarction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The acute coronary syndrome diagnosis includes different classifications of myocardial infarction, which have been shown to differ in their pathology, as well as their early and late prognosis. These differences may relate to the underlying extent of infarction and/or residual myocardial ischemia. The study aim was to compare scar and ischemia mass between acute non-ST elevation myocardial infarction (NSTEMI), ST-elevation MI with Q-wave formation (Q-STEMI) and ST-elevation MI without Q-wave formation (Non-Q STEMI) in-vivo, using cardiovascular magnetic resonance (CMR).</p> <p>Methods and results</p> <p>This was a prospective cohort study of twenty five consecutive patients with NSTEMI, 25 patients with thrombolysed Q-STEMI and 25 patients with thrombolysed Non-Q STEMI. Myocardial function (cine imaging), ischemia (adenosine stress first pass myocardial perfusion) and scar (late gadolinium enhancement) were assessed by CMR 2–6 days after presentation and before any invasive revascularisation procedure. All subjects gave written informed consent and ethical committee approval was obtained. Scar mass was highest in Q-STEMI, followed by Non-Q STEMI and NSTEMI (24.1%, 15.2% and 3.8% of LV mass, respectively; p < 0.0001). Ischemia mass showed the reverse trend and was lowest in Q-STEMI, followed by Non-Q STEMI and NSTEMI (6.9%, 14.7% and 19.9% of LV mass, respectively; p = 0.012). The combined mass of scar and ischemia was similar between the three groups (p = 0.17). The ratio of scar to ischemia was 3.5, 1.0 and 0.2 for Q-STEMI, Non-Q STEMI and NSTEMI, respectively.</p> <p>Conclusion</p> <p>Prior to revascularisation, the ratio of scar to ischemia differs between NSTEMI, Non-Q STEMI and Q-STEMI, whilst the combined scar and ischemia mass is similar between these three types of MI. These results provide in-vivo confirmation of the diverse pathophysiology of different types of acute myocardial infarction and may explain their divergent early and late prognosis.</p

    Shoot yield drives phosphorus use efficiency in Brassica oleracea and correlates with root architecture traits

    Get PDF
    The environmental and financial costs of using inorganic phosphate fertilizers to maintain crop yield and quality are high. Breeding crops that acquire and use phosphorus (P) more efficiently could reduce these costs. The variation in shoot P concentration (shoot-P) and various measures of P use efficiency (PUE) were quantified among 355 Brassica oleracea L. accessions, 74 current commercial cultivars, and 90 doubled haploid (DH) mapping lines from a reference genetic mapping population. Accessions were grown at two or more external P concentrations in glasshouse experiments; commercial and DH accessions were also grown in replicated field experiments. Within the substantial species-wide diversity observed for shoot-P and various measures of PUE in B. oleracea, current commercial cultivars have greater PUE than would be expected by chance. This may be a consequence of breeding for increased yield, which is a significant component of most measures of PUE, or early establishment. Root development and architecture correlate with PUE; in particular, lateral root number, length, and growth rate. Significant quantitative trait loci associated with shoot-P and PUE occur on chromosomes C3 and C7. These data provide information to initiate breeding programmes to improve PUE in B. oleracea

    Investigation into diagnostic accuracy of common strategies for automated perfusion motion correction

    Get PDF
    Respiratory motion is a significant obstacle to the use of quantitative perfusion in clinical practice. Increasingly complex motion correction algorithms are being developed to correct for respiratory motion. However, the impact of these improvements on the final diagnosis of ischemic heart disease has not been evaluated. The aim of this study was to compare the performance of four automated correction methods in terms of their impact on diagnostic accuracy. Three strategies for motion correction were used: (1) independent translation correction for all slices, (2) translation correction for the basal slice with transform propagation to the remaining two slices assuming identical motion in the remaining slices, and (3) rigid correction (translation and rotation) for the basal slice. There were no significant differences in diagnostic accuracy between the manual and automatic motion-corrected datasets (p=0.88). The area under the curve values for manual motion correction and automatic motion correction were 0.93 and 0.92, respectively. All of the automated motion correction methods achieved a comparable diagnostic accuracy to manual correction. This suggests that the simplest automated motion correction method (method 2 with translation transform for basal location and transform propagation to the remaining slices) is a sufficiently complex motion correction method for use in quantitative myocardial perfusion
    • …
    corecore